• Epoxy Resin Solid Insulation Pole Mounted Auto Circuit Recloser
  • Epoxy Resin Solid Insulation Pole Mounted Auto Circuit Recloser
  • Epoxy Resin Solid Insulation Pole Mounted Auto Circuit Recloser

Epoxy Resin Solid Insulation Pole Mounted Auto Circuit Recloser

Breaking Capacity: Mv Auto Recloser
Operation: Electric Type
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Pole Mounted
Structure: Epoxy Resin Solid Insulation Pole
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
FAR Series
Poles Number
3
Type
Circuit Breaker
Function
Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CCC
Transport Package
Seaworthy Wooden Case
Specification
Epoxy resin solid insulation Pole
Trademark
Farady
Origin
China (Mainland)
HS Code
8535900090
Production Capacity
10000 Per Year

Product Description

++++General
Farady Electric strives to bring our customers the latest technology and competitive pricing and best service for pole
mounted Auto circuit recloser
The FAR series Auto circuit recloser can use on overhead distribution lines as well as distribution substation applications
for all voltage classes 11kV up to 38kV at 50/60HZ power system. And its rated current can reach 1600A.
The FAR series Auto circuit recloser integrates the functions of control, protection, measurement,communication,fault
detection,on-line monitoring of closing or opening.comply to IEC62271 and ANSI/IEEE C37.60 standard
++++Service environment
a) Air temperature: Maximum temperature: +85ºC; Minimum temperature:-45ºC
b) Humidity: Monthly average humidity 95%; Daily average humidity 90% .
c) Altitude above sea level: Maximum installation altitude: 2500m or more higher.
d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
e) No frequent violent shake
++++Offering
With optional classes for rated current range:
Rating voltage available from 15kV-38kV
Rating current available from 200A to 1600A
Breaking capacity from 12.5kA-31.5kA
With optional classes for installation styles:
Three phase, vacuum recloser.
With optional relay protection curves for user choice:
Instantaneous over-current protection.
Timing over-current protection.
Negative sequence over-current protection.
Directional over-current protection(*).
Over-voltage protection.
Under voltage protection.
With optional choice by locally or remotely.
With optional communication protocols & I/O port for user choice:
RS-232 and RS-485 ports supporting.
DNP3.0 communication protocol support(*).
Modbus communication protocol is optional(*).
IEC 60870-5-101 communication protocol support.
The recloser can communicate through GPRS(Or GSM) modem with English or Chinese languege (*).
With optional measurement functions for user:
Rated currents, System phase current.
Rated voltages, System phase voltage& secondary low voltage power supply voltage.
Frenquency, power(kWh), reactive power(kVarh),power factor .
With optional reclosing interval for user pre-program:
Reclosing times setting support. Dead time setting support.
With events recording function:
SOE 64 operations record.
Fault record and normal operation record.
Note: (*) mean should customized by manufacturer if needed.
++++Recloser feature
Outline of recloser:
The FAR series vacuum recloser is mainly combined
with integration terminal, current transformer, permanent
magnetic actuator and its recloser controller.
The recloser tank feature:
The Vacuum recloser tanks are manufactured from
304#grade stainless steel and are powder coated
a light grey colour.
Whole recloser IP65 protection class, equipped with
a auxiliary plug to connect with recloser controller by
control cable, Diameter Max22mm, 6 M length(8M for special). .
Its can performance serve more than 20 years long term under heavy duty circumstance.
The recloser vacuum embedded pole feature:
The recloser's vacuum interrupter insert in
Outdoor expoxy resin with a high reliable, stable material:
With excellent electric insulation,
weather resistance, ozone, biological inertia,
can be stand under the long-term use in -55 ~ +200 ºC.
Creepage Distances of FAR
Epoxy Resin Solid Insulation Pole Mounted Auto Circuit Recloser
T to T* -----Terminal to terminal creepage
T to G/E* -----Terminal to ground/earth creepage
Technical data
Epoxy Resin Solid Insulation Pole Mounted Auto Circuit Recloser
Outline & Sizes for FAR
Epoxy Resin Solid Insulation Pole Mounted Auto Circuit Recloser

Packing & Transportation
Epoxy Resin Solid Insulation Pole Mounted Auto Circuit Recloser

About us


Epoxy Resin Solid Insulation Pole Mounted Auto Circuit Recloser



Zhejiang Farady Powertech Co.,Ltd

TEL:0086-0577-61512688

Fax:0086-0577-61510628

Http:// faradypowertech.en.made-in-china.com

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
7.67 Million USD
Plant Area
3775 square meters